특징 |
1. 0 ~300Vac, 40 ~ 450 Hz 넓은 가변 대역 |
2. 3개의 설정 저장 메모리 |
3. PWM Switch 방식의 높은 효율 |
4. 높은 Crest Factor 3:1 |
5. 500VA ~ 2KVA 용량 제품 군 |
6. 과부하, Short, 온도 보호기능 |
7. 용량 대비 작고 가벼운 사이즈 2 KVA, 2U(8.9Cm) Size |
8. Optional High resolution Power meter (0.1mA/0.01W) 내장 가능 |
MODEL | 6905 | 6910 | 6920 | 6940 | ||
INPUT | ||||||
Phase |
1 phase | |||||
Voltage | 110 / 220Vac±10% | 220Vac±10% | ||||
Frequency |
50 / 60 Hz | |||||
AC OUTPUT | ||||||
Power rating | 500VA | 1KVA | 2KVA | 4KVA | ||
Max. Current (r.m.s) | 0-150V | 4.6A at 110V | 9.2A at 110V | 18.4A at 110V | 36.8A at 110V | |
0-300V | 2.3A at 220V | 4.6A at 220V | 9.2A at 220V | 18.4A at 220V | ||
Phase |
1 phase / 2W | |||||
Total Harmonic Distortion (T.H.D) |
< 0.5% 40 - 100Hz , <1% at 101-450Hz (Resistive Load) | |||||
Crest Factor |
≧3 | |||||
Load Regulation |
± (0.5% of output +0.5V) at Resistive Load | |||||
Response Time |
< 400usec | |||||
SETTINGS | ||||||
Voltage | Range |
0-150V/0-300V Selectable | ||||
Resolution |
0.1V | |||||
Accuracy |
±(1% of setting + 2counts) | |||||
Frequency | Range |
40-450Hz Full Range Adjust | ||||
Resolution |
0.1Hz at 40 - 99.9Hz , 1Hz at 100-450Hz | |||||
Accuracy |
±0.03% of setting | |||||
DC OUTPUT (Option) | ||||||
Max. Power |
250W |
500W |
1000W |
2000W | ||
Max. Current |
0-200V |
2.3A |
4.6A |
9.2A |
18.4A | |
0-400V |
1.1A |
2.3A |
4.6A |
9.2A | ||
SETTINGS | ||||||
Voltage |
Range |
0-200V / 0-400V Selectable | ||||
Resolution |
0.1V | |||||
Accuracy |
±(1% of setting + 2counts) | |||||
Ripple and Noise (RMS) |
Range : 0-200V <250mV; Range : 0-400V <400mV |
Range : 0~200V <350mV; Range : 0~400V <550mV | ||||
Ripple and Noise (p-p) |
<2Vp-p |
<3.0Vp-p | ||||
MEASUREMENT | ||||||
Voltage (AC & DC) |
Range |
0.0-400.0V | ||||
Resolution |
0.1V | |||||
Accuracy |
± (1% of reading + 2counts) | |||||
Frequency |
Range |
0.0-500.0Hz | ||||
Resolution |
0.1Hz | |||||
Accuracy |
±0.1Hz | |||||
Current (AC & DC) |
Range |
0.00 - 54.00A | ||||
Resolution |
0.01A | |||||
Accuracy |
± (1% of reading +5counts) | |||||
Power |
Range |
0 -4000W | ||||
Resolution |
1W | |||||
Accuracy |
± (2% of reading +2counts) | |||||
Power Factor |
Range |
0.000-1.000 | ||||
Resolution |
0.001 | |||||
Accuracy |
W / VA ,Calculated and displayed to three significant digits | |||||
Opt.628 High Measurement Resolution (For 6905, 6910 & 6920) | ||||||
AC OUTPUT | ||||||
Current | Range |
L |
0.000A - 0.600A |
0.000A - 1.200A |
0.000A - 2.400A |
- |
H |
0.50A - 6.00A |
1.00A - 13.00A |
2.00A - 27.00A |
- | ||
Resolution |
L |
0.001A |
- | |||
H |
0.01A |
- | ||||
Accuracy |
± (1% of reading +5counts) |
- | ||||
Power | Range |
L |
0.0W - 60.0W |
0.0W - 120.0W |
0.0W - 240.0W |
- |
H |
50W - 500W |
100W - 1000W |
200W - 2000W |
- | ||
Resolution |
L |
0.1W |
- | |||
H |
1W |
- | ||||
Accuracy |
± (2% of reading +5counts) |
- | ||||
DC OUTPUT(Option) | ||||||
Current | Range |
L |
0.010A - 0.600A |
0.010A - 1.200A |
0.0010A - 2.400A |
- |
H |
0.50A - 3.00A |
1.00A - 6.50A |
2.00A - 13.50A |
- | ||
Resolution |
L |
0.001A |
- | |||
H |
0.01A |
- | ||||
Accuracy |
± (1% of reading +5counts) |
- | ||||
Power | Range |
L |
0.0W - 60.0W |
0.0W - 120.0W |
0.0W - 240.0W |
- |
H |
50W - 250W |
100W - 500W |
200W - 1000W |
- | ||
Resolution |
L |
0.1W |
- | |||
H |
1W |
- | ||||
Accuracy |
± (2% of reading +5counts) |
- | ||||
GENERAL | ||||||
Memory |
3 memories (M1, M2, M3) | |||||
Efficiency |
≧80%(at Full Load ) | |||||
Protection |
Over Power, Over Current, Over Voltage, Over Temperature, Hi- A | |||||
Calibration |
Front Panel Calibration | |||||
Environment |
0-40℃/20-80%RH | |||||
Dimension (W×H×D) mm | 430 x 89 x 300 | 430 x 89 x 400 | 430 x 89 x 500 | 430x 222x 500 | ||
Net Weight | 12.5Kg | 18.2Kg | 30Kg | 65Kg |
상품의 사용후기를 적어주세요.
게시물이 없습니다
상품에 대해 궁금한 점을 해결해 드립니다.
게시물이 없습니다